Abstract and keywords
Abstract (English):
Military units and civil defense units have unused reserves of disinfectant, decontaminating, and decontaminating aqueous solutions. Previous experiments have shown that these solutions may be useful for firefighting purposes. This article describes experiments confirming the potential of using disinfecting, degassing, and decontaminating aqueous solutions as fire extinguishing agents. Fire tests were conducted to determine the fire extinguishing properties of an aqueous sulfonol solution using a Class A fire as an example. A method for assessing the electrical conductivity of a sulfonol solution to determine the critical micelle concentration is presented. The results of an experimenton producing fire-extinguishing foam filled with exhaust gases from an internal combustion engine are presented. The fire-extinguishing effect of this foam is compared to standard (air-filled) foam.

Keywords:
fire extinguishing effect, sulfonol, critical micelle concentration, gas-filled foam
Text
Text (PDF): Read Download
References

1. Meshcheryakov I.V., Alekseik E.B. Prakticheskaya ocenka ognetushashchego potenciala tipovyh dezinficiruyushchih, degaziruyushchih i dezaktiviruyushchih rastvorov na primere eksperimental'nogo ochaga pozhara klassa A // Estestvennye nauki i pozharobezopasnost': problemy i perspektivy issledovanij: sb. materialov Vseros. nauch.-prakt. konf. Ivanovo: Ivanovskaya pozharno-spasatel'naya akademiya GPS MCHS Rossii, 2024. S. 196–198.

2. Buhtoyarov V. I. Uchebnik serzhanta himicheskih vojsk. M.: Voenizdat, 1988. 264 s.

3. Lebedeva N.Sh., Taratanov N.A. Issledovanie fizicheskih i ognetushashchih svojstv pen s celevymi dobavkami // Sovremennye problemy grazhdanskoj zashchity. 2021. № 4 (41). S. 85–93.

4. Tuning stability, rheology, and fire-extinguishing performance of advanced firefighting foam material by inorganic nanoparticle flame retardants / Yu. Sheng [et al.] // Journal of Colloid and Interface Science. 2025. Vol. 677. P. 378–389.

5. Environmentally friendly fluorine-free fire extinguishing agent based on the synergistic effect of silicone, hydrocarbon surfactants and foam stabilizers / G. Zhang [et al.] // Colloids and Surfaces A: Physicochemical and Engineering Aspects. 2024. Vol. 694. P. 134–216.

6. Effect of polyimide with different amount on flame retardant property of silicone foam / J. Ren [et al.] // Green Materials. 2025.

7. Bayanov V.O., Salishcheva O.V. Opredelenie kriticheskoj koncentracii micelloobrazovaniya // Studencheskij nauchnyj forum: materialy IX Mezhdunar. stud. nauch. konf. 2017.

8. Metody opredeleniya kriticheskoj koncentracii micelloobrazovaniya: metod. ukazaniya k vypolneniyu laboratornyh rabot po discipline «Kolloidnaya himiya». Kursk, 2016. 13 s.

9. GOST R 51057–2001. Tekhnika pozharnaya. Ognetushiteli perenosnye. Obshchie tekhnicheskie trebovaniya. Metody ispytanij. Dostup iz inform.-pravovogo portala «Garant».

10. GOST R 8.736–2011. Gosudarstvennaya sistema obespecheniya edinstva izmerenij. Izmereniya pryamye mnogokratnye. Metody obrabotki rezul'tatov izmerenij. Osnovnye polozheniya. Dostup iz inform.-pravovogo portala «Garant».

Login or Create