The problematic issues of the development of an integrated system of fire engine maintenance operational readiness were considered. AK Buster, Ltd Technical complex of improvements and maintaintenance of the vehicle operational readiness carrying out an automated three-step charge lead-acid starter accumulators and the results of the research of accumulators charge was described. The possibility using of the technology complex for charging accumulators in the garage of fire station in order to maintain the operational readiness of fire engines is proved.
fire engine, battery, step charge method, voltage, charge current, current sharing
1. GOST R 53165-2008. Batarei akkumulyatornye svincovye starternye dlya avtotraktornoy tehniki. Obschie tehnicheskie usloviya // StandartGOST.ru (data obrascheniya: 05.05.2016).
2. Sistemnyy podhod k probleme povysheniya operativnoy gotovnosti pozharnyh avtomobiley / M.V. Savin [i dr.] // Pozharnaya bezopasnost'. 2015. № 2. S. 102-106.
3. Kurzukov N.I., Yagnyatinskiy V.M. Avtomobil'nye akkumulyatornye batarei. Osnovy ustroystva i praktiki ekspluatacii. M.: Izd-vo «Russkie akkumulyatory», 2011. 26 s.
4. Suhotin A.M. Spravochnik po elektrohimii. L.: Himiya, 1981. 176 s.
5. Etkins P. Fizicheskaya himiya. M.: MIR, 1980. 535 s.